Chapter 1
Introduction to System Messages for the Cisco MDS 9000 Family
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
The following example system message shows how the variable field might be used:
%MODULE-5-MOD_MINORSWFAIL: Module [dec] reported a failure in service [chars]
In this example,
System log messages begin with a percent sign (%) and are displayed in the following format (see
Table
Syslog Format On a Remote-Logging Server
The syslog format on a remote-logging server is:
month dd hh:mm:ss IP-addr-switch : year month day hh:mm:ss Timezone
description
or
month dd hh:mm:ss IP-addr-switch : year month day hh:mm:ssTimezone
facility-SLOTnumber-severity-MNEMONIC description
or
month dd hh:mm:ss IP-addr-switch : year month day hh:mm:ss Timezone
description
For example:
sep 21 11:09:50 172.22.22.45 : 2005 Sep 04 18:18:22 UTC: %AUTHPRIV-3-SYSTEM_MSG: ttyS1:
togetattr: Input/output error - getty[28224]
switch resident syslog 2005 Sep 4 18:18:22 switch %AUTHPRIV-3-SYSTEM_MSG: ttyS1:
togetattr: Input/output error - getty[28224]
time on MDS : 2005 Sep 4 18:18:22 time on Loggng Server : Sep 21 11:09:50
fc1/13 is not supported
.
Table 1-3
Element
month dd
hh:mm:ss
IP-addr-switch
facility
severity
MNEMONIC
%$VSAN #%$
description
FACILITY
system message refers. A facility is a hardware device, a protocol, a feature, or a module of the system
software.
OL-15956-01
Facility code =MODULE (indicating that it is a module-specific error)
Severity =5 (notification)
Alarm/event code= MOD_MINORSWFAIL
Description of the problem=
[dec] is the module slot number associated with this message.
[chars] is the service name that experienced this failure.
1-3).
System Log Message Format Description
Description
The date and month of the error or event
The time of the error or event
The IP address of the switch
The facility of the error or event (daemon, kernel, VSHD, or other facility)
Single-digit code from 0 to 3 that indicates the severity of the message
Text string that uniquely describes the system message
An optional VLAN ID that appears in the description for messages requiring
VLAN IDs
Text string containing detailed information about the event being reported
is a code consisting of two or more uppercase letters that indicate the facility to which the
Module [dec] reported a failure in service [chars]
:
:
:
Cisco MDS 9000 Family System Messages Reference
System Log Message Format
facility-severity-MNEMONIC
facility-STANDBY-severity-MNEMONIC