Svc-3 - Cisco AJ732A - MDS 9134 Fabric Switch Messages Manual

Cisco mds 9000 family system messages reference (ol-15956-01, april 20078)
Hide thumbs Also See for AJ732A - Cisco MDS 9134 Fabric Switch:
Table of Contents

Advertisement

S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Error Message SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_DUMP_RESTORE_FAILED
) Restore of hardened data failed [chars].
Error Message SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec]
SS_EID_EC_ER_INVALID_BATT_CAPACITY ) Get battery capacity failed [chars].
Error Message
SS_EID_EC_ER_OPEN_COMMITTED_FILE_FAILED ) Error attempting to open file [chars].
Error Message
SS_EID_EC_ER_SET_BATT_THRESHOLD_FAILED ) Set battery threshold failed [chars].
Cisco MDS 9000 Family System Messages Reference
2-318
Restore of customer data failed. This error will be accompanied by other log entries.
Explanation
Examine the log for other error entries and follow the actions recommended.
Recommended Action
If no other entries are found: 1. Re-install the code on the node. The node will have to be removed
and re-added back to the cluster. 2. Ensure that the software is at the latest level on the cluster. If
not, upgrade the cluster and if necessary repeat step 1 with the latest level of code. 3. If the error
continues, ask your support representative for assistance. It may be necessary to replace the Caching
Services Module.
Cisco MDS SAN-OS Release 2.0(1b).
Introduced
The process cannot get the battery capacity, possibly because of communication failures
Explanation
with the control plane processor (CPP) in the line card. The node was rebooted because of this error.
If this error is repeated continuously, follow these steps:1. Reinstall the code
Recommended Action
on the line card. The node(s) will then have to be removed and added back to the cluster. 2. Ensure
that the software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat
Step 1 with the latest level of code. 3. Replace the Caching Services Module, if the error persists.
Cisco MDS SAN-OS Release 1.3(1).
Introduced
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec]
Process cannot open the committed file. Node was rebooted because of this error.
Explanation
Recommended Action
If this error is repeated continuously, follow these steps:1. Reinstall the code
on the line card. The node(s) will then have to be removed and added back to the cluster. 2. Ensure
that the software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat
Step 1 with the latest level of code. 3. Replace the Caching Services Module, if the error persists.
Introduced
Cisco MDS SAN-OS Release 1.3(1).
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec]
The process cannot set the battery threshold, possibly because of fatal communication
Explanation
failures with the power management module in the line card or the power management module has
crashed. Node was rebooted because of this error.
If this error is repeated continuously, follow these steps:1. Reinstall the code
Recommended Action
on the line card. The node(s) will then have to be removed and added back to the cluster. 2. Ensure
that the software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat
Step 1 with the latest level of code. 3. Replace the Caching Services Module, if the error persists.
Cisco MDS SAN-OS Release 1.3(1).
Introduced
Chapter 2
System Messages and Recovery Procedures for the Cisco MDS 9000 Family
OL-15956-01

Advertisement

Table of Contents
loading

Table of Contents