Error Message
Error Message
alarm.
Error Message
temperature alarm. Minor temperature alarm pending.
Error Message
temperature alarm.
Error Message PLATFORM-0-SUP_SPROM_ERROR: Unable to read SPROM for Sup in slot [dec].
Error Message PLATFORM-0-SUP_WRONGSLOTNUM: Supervisor powered up in WRONG SLOT:[dec]
(Serial number [chars]).
Cisco MDS 9000 Family System Messages Reference
2-216
PLATFORM-0-FAIL_REMOVED: Fan module removed before [dec] seconds.
Fan module was removed. This could lead to temperature alarms.
Explanation
Recommended Action
Replace the fan module immediately.
Cisco MDS SAN-OS Release 1.2(2a).
Introduced
PLATFORM-0-MOD_TEMPMAJALRM: Module [dec] reported major temperature
Explanation
Module in the slot exceeded a major temperature threshold.
Enter the show env temperature CLI command or use a similar Fabric
Recommended Action
Manager/Device Manager procedure to collect more information.
Cisco MDS SAN-OS Release 1.2(2a).
Introduced
PLATFORM-0-MOD_TEMPRECOVER: Module [dec] recovered from major
Module recovered from a major temperature threshold. Minor threshold still exceeded.
Explanation
Enter the show env temperature CLI command or use a similar Fabric
Recommended Action
Manager/Device Manager procedure to collect more information.
Cisco MDS SAN-OS Release 1.2(2a).
Introduced
PLATFORM-0-MOD_TEMPSHUTDOWN: Module [dec] powered down due to major
Module shut down because temperature exceeded major threshold.
Explanation
Recommended Action
Enter show env temperature CLI command or use a similar Fabric
Manager/Device Manager procedure to collect more information.
Cisco MDS SAN-OS Release 1.2(2a).
Introduced
The supervisor in the slot named was not able to read its SPROM.
Explanation
No action is required.
Recommended Action
Introduced
Cisco MDS SAN-OS Release 3.0(1).
The supervisor is coming up in wrong slot.
Explanation
No action is required.
Recommended Action
Cisco MDS SAN-OS Release 3.0(1).
Introduced
Chapter 2
System Messages and Recovery Procedures for the Cisco MDS 9000 Family
OL-15956-01