Chapter 2
System Messages and Recovery Procedures for the Cisco MDS 9000 Family
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Error Message
SS_EID_EC_ER_DEACTIVATE_CLUSTER_IP_FAILED ) Deactivate cluster IP failed [chars].
Error Message
SS_EID_EC_ER_DUMP_METADATA_FAILED ) Node assert dump failed [chars].
Error Message
) Internal error - program launch [chars].
OL-15956-01
SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec]
Unable to deactivate the cluster IP for the config node. The cluster IP should be
Explanation
deactivated by other checks. If that is not the case, it may not be possible to execute configuration
commands.
If there is a problem executing configuration commands, follow these steps: 1.
Recommended Action
Shut down the interfaces of the node. This will force the node out of the cluster and should cause
the switch to deactivate the IP address associated with the node. This should restore the ability to
execute configuration commands. 2. If the error persists, reinstall the code on the node. The node
will then have to be removed and added back to the cluster. 3. Ensure that the software is at the latest
level on the cluster. If not, upgrade the cluster and if necessary repeat Step 2 with the latest level of
code. 4. Ask your customer support representative for assistance if the error continues.
Cisco MDS SAN-OS Release 1.3(1).
Introduced
SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec]
A failure occurred writing out a node assert dump. Other log entries may accompany
Explanation
this error.
An initial error will have caused the node assert dump. Examine the log for
Recommended Action
that error and follow the recommended actions for that error. In addition, examine the log for errors
related to the internal disk drive. If errors are found, follow the recommended actions. If no entries
explain the failure to write the dump, then perform the following steps: 1. Reinstall the code on the
node. The node will then have to be removed and added back to the cluster. 2. Ensure that the
software is at the latest level on the cluster. If not, upgrade the cluster with the latest level of code.
3. Ask your customer support representative for assistance, if the error continues. It may be
necessary to replace the Caching Services Module.
Cisco MDS SAN-OS Release 1.3(1).
Introduced
SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_EXECVE_FAILED
The process cannot launch the I/O program. Node was rebooted because of this error.
Explanation
If this error is repeated continuously, follow these steps: 1. Reinstall the code
Recommended Action
on the node. The node will then have to be removed and added back to the cluster. 2. Ensure that the
software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1
with the latest level of code. 3. Ask your customer support representative for assistance, if the error
continues.