Error Message
Attempt to delete SSH key (no effect) [chars].
Error Message
recovery required [chars].
Error Message
data corrupted - node rejected from cluster [chars].
Error Message
data unreadable - node rejected from cluster [chars].
Error Message
not valid [chars].
OL-15956-01
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_ERR_CFG_SSH_KEY_REMOVED )
The svctask rmsshkey command has been invoked. This command has no effect in
Explanation
SAN Volume Controller for Cisco MDS 9000, but is retained for compatibility.
Recommended Action
No action is required.
Introduced
Cisco MDS SAN-OS Release 1.3(1).
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_NODERR_CR_START ) Cluster
The node has detected that cluster recovery is required and is waiting for human
Explanation
intervention to continue.
Contact your customer support representative for assistance.
Recommended Action
Cisco MDS SAN-OS Release 1.3(1).
Introduced
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_NODERR_DATA_CORRUPT ) Node
Explanation
Node data is readable but corrupted. The node has been rejected from the cluster.
1. Reinstall the code on the node. The node will have to be removed and added
Recommended Action
back to the cluster. 2. Ensure that the software is at the latest level on the cluster. If not, upgrade the
cluster and if necessary repeat Step 1 with the latest level of code. 3. If the error continues, ask your
customer service representative for assistance. It may be necessary to replace the Caching Services
Module.
Cisco MDS SAN-OS Release 1.3(1).
Introduced
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_NODERR_DATA_UNREADABLE ) Node
Explanation
Node data could not be read. The node has been rejected from the cluster.
1. Reinstall the code on the node. The node will have to be removed and added
Recommended Action
back to the cluster. 2. Ensure that the software is at the latest level on the cluster. If not, upgrade the
cluster and if necessary repeat Step 1 with the latest level of code. 3. If the error continues, ask your
customer support representative for assistance. It may be necessary to replace the Caching Services
Module.
Cisco MDS SAN-OS Release 1.3(1).
Introduced
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_NODERR_HDW_CONFIG ) Processor
Explanation
The node has detected unexpected differences in the processor vital data.
Reload the node. If the problem persists, replace the Caching Services Module.
Recommended Action
Cisco MDS SAN-OS Release 1.3(1).
Introduced