Platform-1 - Cisco AJ732A - MDS 9134 Fabric Switch Messages Manual

Cisco mds 9000 family system messages reference (ol-15956-01, april 20078)
Hide thumbs Also See for AJ732A - Cisco MDS 9134 Fabric Switch:
Table of Contents

Advertisement

Chapter 2
System Messages and Recovery Procedures for the Cisco MDS 9000 Family
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Error Message PLATFORM-1-MDS9124_FAN_FAIL: Less than 4 required fans operating.
Error Message PLATFORM-1-MOD_PWRDENY: Module [dec] cannot be powered up due to
insufficient power (Serial No. [chars]).
Error Message PLATFORM-1-MDS9124_FAN_FAIL: Less than 4 required fans operating.
Error Message PLATFORM-1-XBAR_PWRDENY: Xbar [dec] can not be powered up due to
insufficient power (Serial number [chars]).
PLATFORM-2
Error Message PLATFORM-2-CASA_FAN_FAIL: Fan module [dec] Failed.
OL-15956-01
A fan module has failed leaving fewer than four total fans operating. This can lead to
Explanation
overheating and temperature alarms.
The fan needs to be replaced. Use the show platform internal info CLI
Recommended Action
command to collect more information.
Cisco MDS SAN-OS Release 3.1(2).
Introduced
Available power in power supplies is not sufficient to power up the module.
Explanation
Verify available power and current usage by entering the show env power CLI
Recommended Action
command or by using a similar Fabric Manager/Device Manager procedure. Refer to power supply
documentation in the relevant hardware installation guide to learn how to increase power supply
capacity.
Cisco MDS SAN-OS Release 1.2(2a).
Introduced
Fan module has failed leaving fewer than four total fans operating. This can lead to
Explanation
overheating and temperature alarms.
Use the show platform internal info CLI command to collect more
Recommended Action
information. Fan needs to be replaced.
Cisco MDS SAN-OS Release 3.1(1).
Introduced
Available power in power supplies is not sufficient to power up the xbar.
Explanation
Verify available power and current usage with the show env power CLI
Recommended Action
command or by using a similar Fabric Manager procedure. See the power supply document on how
to increase power supply capacity.
Cisco MDS SAN-OS Release 3.0(1).
Introduced
Indicated fan module has failed and needs to be replaced. This can lead to overheating
Explanation
and temperature alarms.
Recommended Action
Use the show platform internal info CLI command to collect more
information or use a similar Fabric Manager procedure.