Cisco AJ732A - MDS 9134 Fabric Switch Messages Manual page 358

Cisco mds 9000 family system messages reference (ol-15956-01, april 20078)
Hide thumbs Also See for AJ732A - Cisco MDS 9134 Fabric Switch:
Table of Contents

Advertisement

S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Error Message
SS_EID_VL_ER_DEVICE_RESOURCE_RAN_OUT ) Too many controllers were presented to the
cluster [chars].
Error Message
Recovery Procedure occurred [chars].
Error Message
Disk I/O error [chars].
Error Message
Managed Disk error count threshold exceeded [chars].
Cisco MDS 9000 Family System Messages Reference
2-322
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec]
Explanation
The configuration is not valid. Too many devices have been presented to the cluster or
node.
1. Remove unwanted devices from the Fibre Channel network fabric. 2. Start
Recommended Action
a cluster discovery operation to find devices. 3. List all connected managed disks. Check with the
customer that the configuration is as expected. Mark the error you have just repaired fixed.
Cisco MDS SAN-OS Release 1.3(1).
Introduced
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_VL_ER_IO_ERP ) Error
A managed disk error recovery procedure (ERP) has occurred. This error has been
Explanation
reported because a large number of disk error recovery procedures have been performed by the disk
controller. The problem is probably caused by a failure of some other component on the SAN.
1. View the error log entry and determine the managed disk that was being
Recommended Action
accessed when the problem was detected. 2. Perform the disk controller problem determination and
repair procedures for the managed disk determined in Step 1. 3. Perform Fibre Channel switch
problem determination and repair procedures for the Fibre Channel switches containing the node,
and connected to the disk controller that is managing the managed disk, and any Fibre Channel
switches in the Fibre Channel path between those switches. 4. Mark resolved errors from Steps 2
and 3 as fixed. 5. Take an error log dump if no switch or disk controller failures were resolved in
Steps 2 and 3. Call your customer support representative.
Cisco MDS SAN-OS Release 1.3(1).
Introduced
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_VL_ER_IO_ERROR ) Managed
A managed disk or managed disk controller port has been excluded because of
Explanation
excessive errors or unusual behavior.
1. Repair the enclosure or disk controller. 2. Check the managed disk status.
Recommended Action
If any managed disks show a status of online, mark the error you have just repaired as fixed. If any
managed disks show a status of excluded, include the managed disks and then mark the error as
fixed.
Cisco MDS SAN-OS Release 1.3(1).
Introduced
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_VL_ER_IO_THRESHOLD )
A managed disk or managed disk controller port has been excluded because of
Explanation
excessive errors or unusual behavior.
1. Repair the enclosure or disk controller. 2. Check the managed disk status.
Recommended Action
If any managed disks show a status of online, mark the error you have just repaired as fixed. If any
managed disks show a status of excluded, include the managed disks and then mark the error as
fixed.