-Video Filter: It is the average of digital acquisitions of the signal. The
lower this value, the faster the signal will be displayed but less clearly and
vice versa.
6
Settings for Deviation detection type:
•Alarm Thresholds
-Min Threshold: It indicates how many dB below the reference mask
before trigger the alarm.
-Max Threshold: It indicates how many dB above the reference mask
before trigger the alarm.
-The other parameters are the same that Max/Min detection.
7
After setting the parameters, press "Acquire references" to acquire a
reference spectrum according to the settings.
8
After a few seconds the reference spectrum will appear. If the spectrum is
not right, you can modify any parameter and press "Acquire references"
again until you obtain a valid reference spectrum.
9
Once a proper reference spectrum has been obtained, save by pressing
"Save".
10
Saved reference spectrum will appear on the box "Mask Monitorings".
11
To start a mask monitoring, select a reference spectrum in "Mask
Monitorings", select an input and press "Start Monitoring" to start.
12
Monitoring screen shows measurements and alarms from the last cycle.
When clicking on a channel it will show some additional info.
13
Alarms are notified by sending e-mails to addresses from the e-mailing list.
In order for the equipment to send e-mails, the mail service must be
configured in Preferences, SMTP label (for more details refer to
Options" on page
14
To stop press on "Stop Monitoring" or cancel remote control.
15
All saved data it is available on the "Historical Monitoring" screen.