4
In the "Mask" box, enter the mask value, which should be the same as the
one used by the local network (usually 255.255.255.0; if you do not know
these data see "find out local network data" section).
5
To connect the equipment from an external network, fill in the "Gateway"
with the info obtained from the local network.
6
Press on "Save" and then "Exit" to save changes and exit.
7
Connect the equipment to a data network with Internet access. You can use
an Ethernet cable connected to the IPCTRL port or in case of WiFi network,
connect the USB WiFi adapter, select the network and enter the password.
► Find out Local Network Data (LAN)
1
To obtain data from the Ethernet network where your equipment is
connected, you should use a PC connected to this same network.
2
From the PC click on Start menu in Windows. On the Search box write CMD
and press Enter.
3
In opens a command line in a window. Write IPCONFIG and press enter.
4
It displays a window with some lines with info. On line "Local Network
Ethernet Adapter" see line "IPv4 Address". This is the local IP for your PC.
Write down this IP. Also write down "Subnet Mask" and "Default Gateway".
This data is needed to configure the equipment by hand.
► Remote Access
1
From a remote access device (PC, mobile device) run a standard web
browser (Chrome recommended).
2
On the address bar write the IP address to remotely access the equipment.
3
If the connection is successful, it should appear on screen the webControl
welcome screen (see figure). This screen shows the equipment model and
serial number.
Chapter 10: WEBCONTROL
206
March 2025