Reference Manual
POWER-SUPPLY RECOMMENDATIONS
Figure 300
and
Figure 301
provide recommendations on how to interconnect power supply when not all of the available RF IOs (transmitters
and receivers) are used in the end application. Note that to perform Tx1 tracking calibration or DPD on Tx1, the Rx1 datapath must be available
to observe the Tx output. The same relationship exists between the Tx2 and Rx2. It is not possible to perform Tx1 tracking calibration or DPD
operation on the Tx1 output using Rx2 datapath (and vice versa, Tx2 using Rx1).
Figure 301
provides suggestions to configure 1T1R. In TDD applications, to achieve the lowest possible current consumption in deep sleep
state, use the Rx1 and Tx1 datapaths and disable the Rx2 and Tx2 datapaths.
Once any of the configurations outlined in
correct initialization settings described in the data structure.
analog.com
Figure
299,
Figure
300, or
Figure 301
is implemented, initialize the ADRV9001 device with the
ADRV9001
Rev. A | 314 of 377
Need help?
Do you have a question about the ADRV9005 and is the answer not in the manual?
Questions and answers