Analog Inputs/Outputs (Ais/Aos); Ais; Aos - Siemens SINAMICS V90 Operating Instructions Manual

Hide thumbs Also See for SINAMICS V90:
Table of Contents

Advertisement

4.3.3

Analog inputs/outputs (AIs/AOs)

4.3.3.1

AIs

SINAMICS V90 has two analog input terminals. The input voltage at each analog input
varies with control modes.
Pin No.
19, 20
21, 22
* If the AI input voltage is higher than 10 V, the speed is not limited to the value at 10 V (p29060), but
scaled according to p29060. For example, if p29060 = 3000 rpm, the speed is 3300 rpm at 11 V
and 3600 rpm at 12 V.
Command voltage
The command voltage of the analog inputs always follows the formula below:
V
input
4.3.3.2

AOs

The SINAMICS V90 has two analog outputs. You can find detailed information about these
two analog outputs from the table below:
Pin No.
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2016, A5E36037884-002
Analog input
Analog input 1
Analog input 2
= (AI+) - (AI-)
Analog output
46
Analog output 1
48
Analog output 2
Input voltage
Control mode
0 V to 10 V
0 V to 10 V
-10 V to +10 V
0 V to 10 V
0 V to 10 V
0 V to 10 V
0 V to 10 V
-10 V to +10 V
Output voltage
-10 V to +10 V
-10 V to +10 V
4.3 Control/status interface - X8
Function
PTI
Not used
IPos
Not used
S
Speed setpoint (reference
p29060) *
T
Speed limit (reference
p29060) *
PTI
Torque limit (reference
r0333)
IPos
Torque limit (reference
r0333)
S
Torque limit (reference
r0333)
T
Torque setpoint (refer-
ence r0333)
Function
Analog output 1 for monitoring
Analog output 2 for monitoring
Connecting
99

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics s-1fl6

Table of Contents