4 TRANSMISSION/ RECEPTION/ REPEAT / 4.8 Toggling the Capability to Transmit by Using the PTT (Test PTT)
Control between Enabled and Disabled (Local TX Enable/Disable)
Toggling the Capability to Transmit by Using the PTT (Test PTT) Control between
4.8
Enabled and Disabled (Local TX Enable/Disable)
Local TX Enable/Disable is the function to enable or disable the capability to transmit by using the PTT (Test PTT)
control.
When Local TX Disable is enabled, if the PTT (Test PTT) control is pressed, a Warning Alert Tone (1 beep) sounds
from the repeater and the repeater cannot transmit.
If the configuration of Local TX Enable/Disable is changed by using the Remote Control function of the Web
Tool, transmission by using PTT (Test PTT) can be toggled between enabled and disabled.
Note
・
If Local TX Disable is enabled while the repeater is transmitting, the repeater immediately ends the transmission by using the
PTT (Test PTT) control.
If a PTT configured to have a priority lower than the PTT (Test PTT) control is available for transmission when the repeater
・
ends transmission by using the PTT (Test PTT) control by enabling Local TX Disable while the repeater is transmitting, the
repeater switches the modulation signal line and continues transmission.
(Refer to
Configuring the Priority Order of Transmission (PTT
FUNC (E)/ Ver 2.00
Priority).)