2 GETTING STARTED / 2.4 System Structure
Condition
E008
E009
E202
E204
E205
E206
E207
E208
E209
E210
A Sub Repeater can enter the Active state also occurs when the power source of a Main Repeater is OFF (Power OFF
by the Menu operation of the OLED display).
Note
If the Hot Standby configuration is changed, the repeater restarts automatically in the following combinations:
・
Hot Standby Valid is changed from ON to OFF or OFF to ON.
Hot Standby Valid is ON, and Hot Standby Mode is changed from Main to Sub or Sub to Main.
Virtual IP Address is changed while Hot Standby Valid is ON.
The repeater restarts automatically under the following conditions when the Hot Standby status changes:
・
Entering Failsoft Mode
From the Standby state to the Active state
The interval configured in Interval is counted down from the time configured in Switch Time. If the current time
・
exceeds the Switch Time when the configuration is saved, counting down of the cycle does not start until the
following Switch Time. Even if Off is configured in Interval, the Active state is switched only once at the configured
time of Switch Time.
Configuration using KPG-D7
None
・
Configuration using Web Tool
・
Configuring each item of the Hot Standby function (Maintenance > System > Hot Standby > Hot Standby)
Configuring the items of the Failsoft Mode function (Maintenance > System > Hot Standby > Failsoft Mode)
・
Configuring each item of the Auto Active Status Switch function (Maintenance > System > Hot Standby > Auto
・
Active Status Switch)
Configuring each item of the Virtual IP Address function (Maintenance > System > Hot Standby > Virtual IP
・
Address)
FUNC (E)/ Ver 2.00
Table 2-11 Migrating to Standby State by Firmware
Meaning
DSP Error 1
DSP Error 2
Power Supply Voltage Error
RX PLL Unlock
TX PLL Unlock
Current Consumption (HPA) Error
Temperature (Drive Amp) Error
Temperature (TX Block) Error
Temperature (TCXO) Error
Temperature (HPA) Error