Kenwood NXR-1700 Function Reference page 191

Hide thumbs Also See for NXR-1700:
Table of Contents

Advertisement

13 MANAGING DEVICES ON AN IP NETWORK (SNMP) / 13.2 SNMP Troubleshooting
OID (Object Identifier)
1.3.6.1.4.1.46861.1.1.2.1.8.2
1.3.6.1.4.1.46861.1.1.2.2.7.2
1.3.6.1.4.1.46861.1.1.2.3.1.2
1.3.6.1.4.1.46861.1.1.2.3.2.2
1.3.6.1.4.1.46861.1.1.2.4.3.2
1.3.6.1.4.1.46861.1.1.2.5.5.2
FUNC (E)/ Ver 2.00
Name
Description
Fan Error Detection
Is output when the fan can
no longer spin.
Power Supply Voltage
Is output when the power
Status
supply voltage goes below
the lower limit of the
threshold.
PLL Unlock Detection
Is output when the RX PLL
(RX)
unlocks.
PLL Unlock Detection
Is output when the TX PLL
(TX)
unlocks.
Current Consumption
Is output when an error in
(HPA) Error
the HPA current
consumption is detected.
Temperature (Drive
Is output when an error in
Amp) Error
the Drive Amp temperature
is detected.
190
Trouble Shooting
Confirm the fan status. If a
fan error cannot be
confirmed, contact
JVCKENWOOD sales
company technical staff.
Confirm if the power cord,
etc. is connected to the
repeater and if the value of
the power supply voltage is
within the specification
range.
Restart the repeater
because the PLL IC may
not have the correct data
configuration.
Or, execute Tuning Data >
Restore of the FPU.
Restart the repeater
because the PLL IC may
not have the correct data
configuration.
Or, execute Tuning Data >
Restore of the FPU.
If this problem occurs,
contact JVCKENWOOD
sales company technical
staff.
Stop the repeater
transmission and confirm if
the symptom improves.
If the symptom does not
improve, contact
JVCKENWOOD sales
company technical staff.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nxr-1800Nxr-1700eNxr-1800eNxr-1800e2

Table of Contents