13.2 SNMP Troubleshooting

This section describes the Trap information and excludes the Polling information among the information sent from
SNMP. A Trap and Polling have different mechanisms for obtaining the OID (Object Identifier) information as shown
below:
Trap information: The repeater detects the status change by itself, and the repeater outputs the OID information
spontaneously.
Polling information: When the information acquisition request is made, the repeater outputs the OID information.
The following table describes the Trap of generic MIB supported by the repeater:
Table 13-3 Supported Items of the Repeater in the Generic MIB Trap
OID (Object Identifier)
1.3.6.1.6.3.1.1.5.1
1.3.6.1.6.3.1.1.5.5
FUNC (E)/ Ver 2.00
Name
coldStart
authenticationFailure
Description
Is output when NXR-1700/ NXR-
1800 reboots or recovers from a
power failure.
Is output when a request from
SNMP Manager causes an
authentication error.
188
Trouble Shooting
If no user action is taken or
a power failure has not
occurred, confirm the
NXR-1700/ NXR-1800
status and check for
unauthorized users
because there is a
possibility of unintended
behavior.
Confirm that the
Community Name
configuration is correct.
Also, confirm that there are
no unauthorized users.