1 FUNCTIONS AND PANEL LAYOUT / 1.3 OLED display
Control function that cannot be executed due to the status
Test PTT Control
If the status is TX Disable or Local TX Disable, or if the transmission by PTT with a higher priority than Test PTT is being
executed, transmission cannot be done with Test PTT even if Test PTT is enabled. In this case, when Test PTT Control
is on by rotating the Knob, the background color inversion migrates to the side for on, but the
icon remains displayed
on the side for off. When transmission becomes possible by Test PTT after TX Disable and Local TX Disable are reset
or the transmission by PTT having a higher priority than Test PTT is finished while Test PTT remains on, the
icon
migrates to the side for on, and the transmission by Test PTT starts.
When TX Disable or Local TX Disable is enabled during the transmission by Test PTT and the transmission by PTT
having a higher priority than Test PTT is to start, the background color inversion remains on the side for on, but the
icon migrates to the side for off, and the transmission by Test PTT is finished.
Even if Test PTT remains on, the OLED display turns off when no Knob operation occurs and Screen Off Timer expires
while transmission by Test PTT is disabled. At this time, Test PTT is disabled.
Refer to Screen Off for details of the OLED display lighting during transmission by Test PTT.
Slot Select
During transmission by External PTT, a slot can be selected by rotating the Knob, but the Push operation is disabled
and changing a slot cannot be performed. A slot cannot be changed also during transmission by Test PTT. When moving
from the Test PTT control, Test PTT always becomes off; therefore, Slot Select is not operated by using the Knob during
transmission with Test PTT.