20 MULTI LOADER / 20.4 Operation (from Startup to Firmware Conversion, Transfer, and Transfer Completion)
Item
If the clock of the PC running
the Multi Loader and the
internal clock in the repeater
deviate
If the time on the PC running
the Multi Loader deviates
from the actual time
Handling the daylight saving
time in Specified Time
Handling the time zone in
Specified Time
If the time is configured by
the repeater from the Web
Tool while waiting for the
firmware switch by Specified
Time
If Firmware Update occurs
from WEB while waiting for
the firmware switch (Remote
Reactivation, Specified Time)
FUNC (E)/ Ver 2.00
Table 20-9 Precautions of Reactivation
Description
The Multi Loader does not detect the time deviation of the clock in the repeater.
Therefore, the configured time until the firmware switch starts is configured as the
time indicated by the PC clock; however, the repeater calculates the difference from
the internal clock and starts Reactivation after that time has elapsed.
The Multi Loader does not detect the time deviation of the actual time on the
repeater. Therefore, the time until the firmware switch starts is configured as the
time indicated by the PC clock; however, the repeater calculates the difference from
the internal clock and starts Reactivation after that time has elapsed.
The Multi Loader does not detect the ±1 hour due to the daylight saving time. For
example, if the time for starting the firmware switch is configured across the start of
daylight saving time, Reactivation starts at a timing of ±1 hour after the start of
daylight saving time. Reactivation is only started according to the elapsed time from
the time when the firmware switch is specified in Specified Time.
The Multi Loader does not support the system across time zones. It is assumed
that the PC running the Multi Loader and the targeted repeaters are in the same
time zone. For example, if Specified Time is executed to the repeater in a different
time zone, Reactivation is started according to the elapsed time from the time
specified for the firmware switch with reference to the time zone of the PC running
the Multi Loader.
The repeater starts Reactivation at the time configured in Specified Time with
reference to the time after a change.
For example, if a firmware switch of which Specified Time is 15:00 is in the standby
state, and the current time is 12:00, the time on the repeater is advanced from
12:00 to 9:00 at this point. In this case, Reactivation is started when the time on the
repeater is 15:00 after 6 hours.
Also, if the time after a change exceeds the time specified in Specified Time,
Reactivation is performed when the specified time is exceeded.
Firmware Update of WEB takes precedence, and the state of waiting for the
firmware switch by the Multi Loader is disabled. When Firmware Update by WEB is
complete, the repeater starts up with that firmware.
228