20 MULTI LOADER / 20.4 Operation (from Startup to Firmware Conversion, Transfer, and Transfer Completion)
Reactivation Method
Refer to the following table for the items of Reactivation Method:
Item
Auto Restart (*default)
Remote Reactivation
Specified Time
Date Time
FUNC (E)/ Ver 2.00
Table 20-8 Reactivation Method
Description
If Transfer with Auto Restart configured is performed, the repeater
automatically starts the firmware switch and starts the behavior with the new
firmware after the firmware transfer is complete.
When Remote Reactivation is received, the repeater starts the firmware switch.
If the new firmware has been written by Transfer, the repeater starts the
behavior with the new firmware after the firmware switch is complete.
By using Specified Time, the repeater firmware switch can be started at any
configured date and time.
The time specified in Specified Time is notified as the relative time for the
repeater. This causes the repeater to start the firmware switch after a specified
time has elapsed.
Also, if Remote Reactivation is received while the repeater is waiting for a
firmware switch, the firmware switch starts at that time.
The repeater firmware switch time is configured.
227