4 TRANSMISSION/ RECEPTION/ REPEAT / 4.6 Configuring the Duration of Transmission in the Received Mode
(Signaling Reset Timer)
Receiving Conditions
If conditions 1) to 3) below are all satisfied:
1) The repeater has received a DMR digital signal or an NXDN digital
signal for which the signaling received by the repeater and the
signaling configured for the repeater match.
2) The reception of the DMR digital signal or the NXDN digital signal in
1) has been completed, and the length of time configured in
Signaling Reset Timer elapses.
3) Currently, no signal is being received on the mixed channel used by
the repeater for transmission. Or, the repeater is receiving an analog
signal or a DMR digital signal or an NXDN digital signal for which the
signaling received by the repeater and the signaling configured for the
repeater do not match.
The repeater is receiving an analog signal for which the signaling
received by the repeater and the signaling configured for the repeater
match.
If conditions 1) to 3) below are all satisfied:
1) The repeater has received an analog signal for which the signaling
received by the repeater and the signaling configured for the
repeater match.
2) The reception of the analog signal in 1) has been completed, and the
length of time configured in Signaling Reset Timer is counting
down.
3) Currently, no signal is being received on the mixed channel used by
the repeater for transmission. Or, the repeater is receiving an analog
signal or a DMR digital signal or an NXDN digital signal for which the
signaling received by the repeater and the signaling configured for the
repeater do not match.
If conditions 1) to 3) below are all satisfied:
1) The repeater has received an analog signal for which the signaling
received by the repeater and the signaling configured for the
repeater match.
FUNC (E)/ Ver 2.00
Transmit Mode
Analog
DMR/ NXDN
Analog
DMR/ NXDN
Analog
DMR/ NXDN
Analog
83
Communication Method
for Transmission Using the
PTT (Test PTT and External
PTT) control
Analog
DMR/ NXDN
Analog
Analog
Analog
Analog
Analog

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nxr-1800Nxr-1700eNxr-1800eNxr-1800e2

Table of Contents