21 ERROR MESSAGE LIST FROM REPEATER
Error Code
Item
Temperature (TX Block) Error
E208
Temperature (TCXO) Error
E209
Temperature (HPA) Error
E210
E211
IF IC Error
While any of the E207, E208, and E210 errors occurs, or when any of these errors occurs during transmission, the
repeater transmits after the transmit power is lowered by 12 dB. Even in the state where these errors are resolved during
transmission, the repeater continues to keep the transmit power until the transmission ends. When transmission is
initiated in the state where E207, E208, and E210 errors are all resolved, the repeater executes transmission with the
normal transmit power.
FUNC (E)/ Ver 2.00
Condition of Occurrence
When a TX Block temperature error is
detected
When a TCXO temperature error is
detected
When an HPA temperature error is
detected
CLK_M (AD9864_M) behavior error
231
Threshold
Fixed value
N/A
Fixed value