2 GETTING STARTED / 2.4 System Structure
Figure 2-11 Repeater (Main) Recovery
After a Main Repeater is replaced and the power is on, synchronization between a Main Repeater and a Sub Repeater
is restored when the network connection between a Main Repeater and a Sub Repeater is restored. At this time, a Main
Repeater migrates to the Standby state. A Sub Repeater restores the Hot Standby behavior to maintain the Active state.
Because a Main Repeater and a Sub Repeater are synchronized, if Auto Active Status Switch is configured, the
repeater in the Active state is replaced according to the configuration. Or, the repeater in the Active state can be manually
replaced by Active Status Switch. In addition, the status of each repeater can be confirmed from Hot Standby Status
of the Web Tool and the OLED display.
71
FUNC (E)/ Ver 2.00