Kenwood NXR-1700 Function Reference page 68

Hide thumbs Also See for NXR-1700:
Table of Contents

Advertisement

2 GETTING STARTED / 2.4 System Structure
2 Configuring the FPU
Virtual IP Address (Site 1) and IP Address (Site 2) of NXR-1700_C to which the Conventional IP Network is connected
are configured in Unicast IP Address List for NXR-1700_A and NXR-1700_B.
Configure Unicast IP Address List of NXR-1700_C in the same manner.
Also, the destination IP Address of when the FPU writing is executed is not the Virtual IP Address, but the Own IP
Address of each of NXR-1700_A and NXR-1700_B, which is used for the writing.
Figure 2-7 Write Data to the Repeater (Example of Writing to NXR-1700_A)
Configuration using KPG-D7
・ Configuring Unicast IP Address List ( Edit > Conventional IP Network > Network > Unicast IP Address List)
Configuration using Web Tool
・ Configuring Hot Standby ( Maintenance > System > Hot Standby)
3 Confirming the status
The Hot Standby status of each repeater is confirmed from the Web Tool or OLED display.
Table 2-13 Status Confirmation of the Web Tool or OLED display
Item
Web Tool
General Information
OLED
Network Information
FUNC (E)/ Ver 2.00
Figure 2-6 Unicast IP Address List
NXR-1700_A
Hot Standby Mode
Main
Hot Standby Status
Active
Virtual IP Address
172.16.0.99
Hot Standby Status
HSB Active
Virtual IP Address
172.16.0.99
67
NXR-1700_B
Sub
Standby
172.16.0.99
HSB Standby
172.16.0.99