Power-On Sequence; Power-On Sequence When Not Using Ram Backup - Mitsubishi Electric M32R Series User Manual

Mitsubishi 32-bit risc single-chip microcomputers
Table of Contents

Advertisement

20

20.2 Power-On Sequence

20.2.1 Power-On Sequence When Not Using RAM Backup

The diagram below shows a power-on sequence (5.0 V, 3.3 V power supply) of the M32R/E when
not using RAM backup.
VCCE
AVCC0,
AVCC1
VREF0,
VREF1
RESET
VDD
VCCI
FVCC
OSC-VCC
: Turn on the 3.3 V power supply after turning on the 5 V power supply.
:
After turning on all power supplies and holding the RESET pin low for an oscillation
stabilization time, release the RESET pin input back high (to deactivate reset).
Note: Power-on limitations
• VDD
• VCCE
Figure 20.2.1 Power-On Sequence When Not Using RAM Backup
POWER-UP/POWER-SHUTDOWN SEQUENCE
5V
0V
5V
0V
5V
0V
1
0V
3.3V
0V
3.3V
0V
3.3V
0V
3.3V
0V
____________
OSC-VCC
VCCI
VCCI, FVCC, OSC-VCC
2
____________
FVCC
20-3
20.2 Power-Up Sequence
5V
Ver.0.10