Tml Control Registers - Mitsubishi Electric M32R Series User Manual

Mitsubishi 32-bit risc single-chip microcomputers
Table of Contents

Advertisement

10

10.6.4 TML Control Registers

TML0 Control Register (TML0CR)
D8
TML0SS0 TML0SS1 TML0SS2 TML0SS3
D
Bit Name
8
TML0SS0
(TML0 measure 0 source selection)
9
TML0SS1
(TML0 measure 1 source selection)
10
TML0SS2
(TML0 measure 2 source selection)
11
TML0SS3
(TML0 measure 3 source selection)
12-14
No functions assigned
15
TML0CKS
(TML0 clock source selection)
The TML0 Control Register is used to select TML0 input event and the counter clock source.
Note: The counter can be written to normally only when the selected clock source is a 1/2 internal peripheral
clock. When using any other clock source, you cannot write to the counter normally. Under this
condition, do not write to the counter.
9
10
11
10-152
MULTIJUNCTION TIMERS
10.6 TML (Input-related 32-bit Timer)
<Address: H'0080 03EB>
12
13
14
Function
0: External input TIN23
1: Input event bus 0
0: External input TIN22
1: Input event bus 1
0: External input TIN21
1: Input event bus 2
0: External input TIN20
1: Input event bus 3
0: 1/2 internal peripheral clock
1: Clock bus 1
D15
TML0CKS
<When reset:H'00>
R
W
0
Ver.0.10