Mitsubishi Electric M32R Series User Manual page 423

Mitsubishi 32-bit risc single-chip microcomputers
Table of Contents

Advertisement

10
TML1 Control Register (TML1CR)
D8
TML1SS0 TML1SS1 TML1SS2 TML1SS3
D
Bit Name
8
TML1SS0
(TML1 measure 0 source selection)
9
TML1SS1
(TML1 measure 1 source selection)
10
TML1SS2
(TML1 measure 2 source selection)
11
TML1SS3
(TML1 measure 3 source selection)
12-14
No functions assigned
15
TML1CKS
(TML1 clock source selection)
The TML1 Control Register is used to select TML1 input event and the counter clock source.
Note: The counter can be written to normally only when the selected clock source is a 1/2 internal peripheral
clock. When using any other clock source, you cannot write to the counter normally. Under this
condition, do not write to the counter.
9
10
11
10-153
MULTIJUNCTION TIMERS
10.6 TML (Input-related 32-bit Timer)
<Address: H'0080 0FEB>
12
13
14
Function
0: External input TIN33
1: Input event bus 0
0: External input TIN32
1: Input event bus 1
0: External input TIN31
1: Input event bus 2
0: External input TIN30
1: Input event bus 3
0: 1/2 internal peripheral clock
1: Clock bus 1
D15
TML1CKS
<When reset:H'00>
R
W
0
Ver.0.10