Transmitting Remote Frames; Remote Frame Transmit Procedure - Mitsubishi Electric M32R Series User Manual

Mitsubishi 32-bit risc single-chip microcomputers
Table of Contents

Advertisement

13

13.7 Transmitting Remote Frames

13.7.1 Remote Frame Transmit Procedure

The following describes the procedure for transmitting remote frames.
(1) Initializing the CAN Message Slot Control Register
Initialize the CAN Message Slot Control Register for the slot in which you want to transmit by
writing H'00 to the register.
(2) Confirming that transmission is idle
Read the CAN Message Slot Control Register after being initialized and check the TRSTAT
(Transmit/Receive Status) bit to see that transmission has stopped and remains idle. If this bit =
1, it means that the CAN module is accessing the message slot, so you need to wait until the bit
is cleared.
(3) Setting transmit ID
Set the ID to be transmitted in the message slot.
(4) Setting the Extended ID Register
Set the corresponding bit of the Extended ID Register to 0 when you want to transmit the frame
as a standard frame or 1 when you want to transmit the frame as an extended frame.
(5) Setting the CAN Message Slot Control Register
Write H'A0 to the CAN Message Slot Control Register to set the TR (Transmit Request) and RM
(Remote) bits to 1.