Interrupt Control Unit - Mitsubishi Electric M32R Series User Manual

Mitsubishi 32-bit risc single-chip microcomputers
Table of Contents

Advertisement

10

10.2.6 Interrupt Control Unit

The interrupt control unit controls the interrupt signals sent to the interrupt controller by each timer.
Following 22 timer interrupt control registers are provided for each timer.
• TOP Interrupt Control Register 0 (TOPIR0)
• TOP Interrupt Control Register 1 (TOPIR1)
• TOP Interrupt Control Register 2 (TOPIR2)
• TOP Interrupt Control Register 3 (TOPIR3)
• TIO Interrupt Control Register 0 (TIOIR0)
• TIO Interrupt Control Register 1 (TIOIR1)
• TIO Interrupt Control Register 2 (TIOIR2)
• TMS Interrupt Control Register (TMSIR)
• TIN Interrupt Control Register 0 (TINIR0)
• TIN Interrupt Control Register 1 (TINIR1)
• TIN Interrupt Control Register 2 (TINIR2)
• TIN Interrupt Control Register 3 (TINIR3)
• TIN Interrupt Control Register 4 (TINIR4)
• TIN Interrupt Control Register 5 (TINIR5)
• TIN Interrupt Control Register 6 (TINIR6)
• TIN Interrupt Control Register 7 (TINIR7)
• TOD0 Interrupt Mask Register (TOD0IMA)
• TOD0 Interrupt Status Register (TOD0IST)
• TOD1 Interrupt Mask Register (TOD1IMA)
• TOD1 Interrupt Status Register (TOD1IST)
• TOM0 Interrupt Mask Register (TOM0IMA)
• TOM0 Interrupt Status Register (TOM0IST)
For interrupts which have only one source of interrupt in one interrupt table, no interrupt control
registers are provided in the timer, and the interrupt status flags are automatically managed within
the interrupt controller. For details, refer to Chapter 14, "Interrupt Controller."
• TOP10
• TID0
• TID1
• TID2
MJT Output Interrupt 5 (IRQ5)
TID0 Output Interrupt (IRQ14)
TID1 Output Interrupt (IRQ15)
TID2 Output Interrupt (IRQ17)
10-37
MULTIJUNCTION TIMERS
10.2 Common Units of Multijunction Timer
Ver.0.10

Advertisement

Table of Contents
loading