A-D Scan Mode Register 1 - Mitsubishi Electric M32R Series User Manual

Mitsubishi 32-bit risc single-chip microcomputers
Table of Contents

Advertisement

11

11.2.4 A-D Scan Mode Register 1

A-D0 Scan Mode Register 1 (AD0SCM1)
D8
D
Bit Name
8
No functions assigned
9
AD0CSPD
(A-D0 conversion rate selection)
10,11
No functions assigned
12-15
AN0SCAN
(A-D0 scan loop selection)
A-D0 Scan Mode Register 1 is used to control operation of the A-D0 converter during scan mode.
9
10
AD0CSPD
11-30
11.2 A-D Converter Related Registers
11
12
13
AN0SCAN
Function
0: Normal
1: x2
<When written to>
01XX: 4-channel scan
10XX: 8-channel scan
11XX: 16-channel scan
00XX: 16-channel scan
<When read during conversion>
0000: Converting AD0IN0
0001: Converting AD0IN1
0010: Converting AD0IN2
0011: Converting AD0IN3
0100: Converting AD0IN4
0101: Converting AD0IN5
0110: Converting AD0IN6
0111: Converting AD0IN7
1000: Converting AD0IN8
1001: Converting AD0IN9
1010: Converting AD0IN10
1011: Converting AD0IN11
1100: Converting AD0IN12
1101: Converting AD0IN13
1110: Converting AD0IN14
1111: Converting AD0IN15
A-D CONVERTERS
<Address: H'0080 0085>
14
D15
<When reset:H'00>
R
0
0
Ver.0.10