6-3-4-5. Bottom Hold
Capable of setting the "Delay Time." However, the "Detect Time", "Comparison Mode", and "Display Mode" cannot be set.
(A) Behavior with control input signal
When the HOLD command is turned ON
and after the lapse of delay time, the bottom
value is detected and indicated until the
HOLD command is turned OFF.
The detection of the bottom value and hold
display are released when the HOLD
command is turned OFF or RESET
command is turned ON.
(B) Behavior with key operation
When the
key is pressed and after
the lapse of delay time, the detecting block is
started and the bottom value is displayed
until the HOLD key is pressed for the
second time.
Press the
key for the second time
and the detecting block ends.
6-3-4-6. Arbitrary Point Hold
Capable of setting the "Delay Time." However, the "Detect Time", "Comparison Mode", and "Display Mode" cannot be set.
(A) Behavior with control input signal
Holds the measured value of the arbitrary
point.
The detecting point is the time when the
HOLD command is turned ON and after the
lapse of delay time.
The measured value is kept hold until the
command is turned OFF.
The kept hold measured value is cancelled
when the HOLD command is turned OFF or
RESET command is turned ON.
(B) Behavior with key operation
When the
key is pressed and after
the lapse of delay time, the holding block is
started and the displayed value at the end f
the delay time is kept hold.
Press the
key for the second time
and the detecting block ends.
(It means cancelling the holding value.)