<Direct operations from the "Measuring" window>
1) Press any of the
"Measuring" window.
2) The window changes to the setting window of the target compared
values.
Input a setting value with the numeric keyboard and press the
key for registering.
<Classifications of comparators for the [Block Peak-Bottom] and [Time Peak-Bottom]>
For the [Block Peak-Bottom] and [Time Peak-Bottom], control outputs and setting values of every comparator are
classified as follows.
Classification
Upper limit of the peal value
Lower limit of the peak value
Upper limit of the bottom value
Lower limit of the bottom value
NOTE
Classifications for the control outputs, keys, and setting values are fixed.
(2) Hysteresis Width
Common to all comparators. Sets a width between the comparator's ON and OFF.
<Setting Range>
0 to 9999 (count)
<How to operate>
1) Press the
2) Press the
window.
3) Input a setting value with the numeric keyboard and press the
key for registering.
Control Output
HH comparator
LL comparator
HI comparator
LO comparator
key on the "Comparison Setting (1/2)" window.
key on the "Comparison Setting (2/2)"
key on the
Keys and setting values
HI1 Compared Value
LO1 Compared Value
HI2 Compared Value
LO2 Compared Value