5) TEDS Error
Displaying
Content:
Cause:
How to Check:
Error during the measurement
Switch
Hold
Zero
LL
LO
OK
HI
HH
Detecting
Measure 0
Holding
Time Peak
Input Value +Over
Input value ex-
ceeds +3.2mV/V
kN
999.99
500.00
HH
HI
- 150.00
- 999.99
LO
LL
Switch
Hold
Zero
LL
LO
OK
HI
HH
Detecting
Measure 0
Holding
Time Peak
No-load Zero Error
Stopping no-load
Zero
kN
999.99
500.00
HH
HI
- 150.00
- 999.99
LO
LL
Switch
Cursor ON
Wave Clear
kN
300.00
kN
Input Value +Over
Input value ex-
ceeds +3.2mV/V
Y-axis
-200.00
0.0
RECORD
X-axis
Start
Error during the setting
Input value
Input value ex-
Measure
ceeds +3.2mV/V
+over
Calibration is conducted with
Calibration
sensor by 'Manual Input','TEDS
Auto'or'TEDS Part'Cal.
'Smoothing','Additional Value'
Input Set
and 'Zero Compensation'are set
The sensor output is monitored
'Comparison Set'and 'Measure
Meas.Condition Set
Mode Set'are set as measure-
ment condition.
The necessary setting to dis-
Wave Display Set
play the wave such as 'X-axis'
and 'Y-axis'are set.
Next
No-load Zero
Stoping no-load
Measure
Zero
Error
Calibration is conducted with
Calibration
sensor by 'Manual Input','TEDS
Auto'or'TEDS Part'Cal.
'Smoothing','Additional Value'
Input Set
and 'Zero Compensation'are set
The sensor output is monitored
'Comparison Set'and 'Measure
Meas.Condition Set
Mode Set'are set as measure-
ment condition.
The necessary setting to dis-
Wave Display Set
play the wave such as 'X-axis'
and 'Y-axis'are set.
Next
Stops the reading of the TEDS information.
The TEDS information may not be read correctly or the interface may not corresponding
to the IEEE1451.4 Mixed Mode Transducer Interface Class 2.
In addition, the transducer may be faulty, cable may be disconnected or may be incorrectly
connected.
The cable length may exceeds 30 m.
Check that the connecting transducer is corresponding to the TEDS.
Check that the connecting transducer has information based on the IEEE template No. 33.
Check that the cable length is 30 m or less.
Set
Switch
Hold
LL
LO
OK
HI
Detecting
Holding
Input Value -Over
Input value is
below -3.2mV/V
999.99
HH
HI
- 150.00
LO
LL
Set
Switch
Hold
LL
LO
OK
HI
Detecting
Holding
Sens.Regist.Error
Stopping sens.
registering
999.99
HH
HI
- 150.00
LO
LL
Set
10.0
S
Input value
Input value is
below -3.2mV/V
-over
Calibration is conducted with
Calibration
sensor by 'Manual Input','TEDS
Auto'or'TEDS Part'Cal.
'Smoothing','Additional Value'
Input Set
and 'Zero Compensation'are set
The sensor output is monitored
'Comparison Set'and 'Measure
Meas.Condition Set
Mode Set'are set as measure-
ment condition.
The necessary setting to dis-
Wave Display Set
play the wave such as 'X-axis'
and 'Y-axis'are set.
1 / 2
Sens.Regis-
Stoping sens.
registering
tering Error
Calibration is conducted with
Calibration
sensor by 'Manual Input','TEDS
Auto'or'TEDS Part'Cal.
'Smoothing','Additional Value'
Input Set
and 'Zero Compensation'are set
The sensor output is monitored
'Comparison Set'and 'Measure
Meas.Condition Set
Mode Set'are set as measure-
ment condition.
The necessary setting to dis-
Wave Display Set
play the wave such as 'X-axis'
and 'Y-axis'are set.
1 / 2
Zero
Set
Switch
Hold
HH
LL
LO
Measure 0
Detecting
Time Peak
Holding
Indicated Value +Over
Indicated value
exceeds +99999
kN
500.00
999.99
HH
- 999.99
- 150.00
LO
Zero
Set
Switch
Hold
HH
LL
LO
Measure 0
Detecting
Time Peak
Holding
Stopping TEDS
calibration
kN
500.00
999.99
HH
- 999.99
- 150.00
LO
Indicated
Indicated value
Measure
exceeds +99999
value +over
Calibration
Input Set
Meas.Condition Set
Wave Display Set
Next
1 / 2
TEDS
Stoping TEDS
Measure
calibration
Error
Calibration
Input Set
Meas.Condition Set
Wave Display Set
Next
1 / 2
134
Zero
Set
Switch
OK
HI
HH
Detecting
Measure 0
Holding
Time Peak
kN
500.00
HI
HH
- 999.99
LO
LL
Switch
Zero
Set
OK
HI
HH
Measure 0
Time Peak
TEDS Error
kN
500.00
HI
- 999.99
LL
Indicated
Measure
value -over
Calibration is conducted with
Calibration
sensor by 'Manual Input','TEDS
Auto'or'TEDS Part'Cal.
'Smoothing','Additional Value'
Input Set
and 'Zero Compensation'are set
The sensor output is monitored
'Comparison Set'and 'Measure
Meas.Condition Set
Mode Set'are set as measure-
ment condition.
The necessary setting to dis-
Wave Display Set
play the wave such as 'X-axis'
and 'Y-axis'are set.
Next
1 / 2
Measure
Calibration is conducted with
sensor by 'Manual Input','TEDS
Auto'or'TEDS Part'Cal.
'Smoothing','Additional Value'
and 'Zero Compensation'are set
The sensor output is monitored
'Comparison Set'and 'Measure
Mode Set'are set as measure-
ment condition.
The necessary setting to dis-
play the wave such as 'X-axis'
and 'Y-axis'are set.
Next
1 / 2
Hold
Zero
Set
LL
LO
OK
HI
HH
Measure 0
Time Peak
Indicated Value -Over
Indicated value
is below -99999
kN
999.99
500.00
HI
- 150.00
- 999.99
LL
Zero
Set
LL
LO
OK
HI
HH
Input Value +Over
Input value ex-
ceeds +3.2mV/V
kN
Indicated value
Measure
is below -99999
Calibration is conducted with
sensor by 'Manual Input','TEDS
Auto'or'TEDS Part'Cal.
'Smoothing','Additional Value'
and 'Zero Compensation'are set
The sensor output is monitored
'Comparison Set'and 'Measure
Mode Set'are set as measure-
ment condition.
The necessary setting to dis-
play the wave such as 'X-axis'
and 'Y-axis'are set.
Next
1 / 2