– Install air filter housing
⇒ "2.2 Removing and installing air filter housing", page 239
Caution
There is a risk of destruction of control units as a result of over‐
voltage.
♦ Do not use charger for jump starting!
– Top up and bleed cooling system
– Interrogate all event memories and delete all event entries
which are caused by removing and installing the engine ⇒ Ve‐
hicle diagnostic tester.
After deleting the event memory of the engine control unit the
readiness code must be re-generated.
Note
Only re-use drained coolant if the cylinder head or cylinder
♦
block has not been replaced.
Dirty coolant must not be used again.
♦
Tightening torques
Note
Tightening torques apply only for lightly greased, oiled,
♦
phosphatized or blackened nuts and screws.
Other lubricants such as engine and gearbox oil are allowed,
♦
but no lubricants containing graphite.
Do not use degreased parts.
♦
Component
Screws and nuts
deviations:
Engine/gearbox connecting screws ⇒ Gearbox; Rep. gr. 34
Screws for assembly bracket:
♦ Assembly bracket
⇒ "2.1 Unit mounting - summary of components",
page 26
.
1.2/63; 77 kW TSI engine - Edition 11.2014
⇒ page 148
.
Nm
M6
9 Nm
M7
15 Nm
M8
20 Nm
M10
40 Nm
M12
65 Nm
Octavia III 2013 ➤ , Octavia III 2014 ➤
.
1. Removing and installing engine
25