Specifications; Options And Accessories; Stt04 Terminal Specifications - ABB STT04 Instruction Manual

Smart transmitter terminal
Table of Contents

Advertisement

INTRODUCTION

SPECIFICATIONS

OPTIONS AND ACCESSORIES

SPECIFICATIONS
1 - 4
Table
1-4
lists the performance specifications of the STT04 terminal.
Table 1-4. STT04 Terminal Specifications
Property
Display format
Type
Number of rows
Characters per row
Configuration storage
capacity
Keyboard type
Clip Leads Cable length
Temperature limits
Operating
Storage
Humidity limits
Batteries
Type
Run time
Charging time
Weight
Dimensions (HxWxD)
Case material
1
Agency certifications
NOTE:
1. Hazardous location approvals for use in flammable atmospheres are for ambient conditions of
-25° to 40°C (-13° to 104°F), 86 to 106 kPa (12.5 to 15.7 psi) with a maximum oxygen concentration
of 21 percent.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
The STT04 has a nomenclature option for a carrying case, refer to
Table
1-2
for nomenclature details. Spare parts are recommended to
be kept on hand to minimize down time, refer to
MENT AND UPGRADE
Characteristic/ Value
LCD
4
20
100 configurations
Tactile feedback embossed membrane; 32 keys
1.8 m (5 ft 10 in.)
-10° to 60°C (14° to 140°F)
-20° to 70°C (-4° to 158°F)
95%, noncondensing
AA NiCd rechargeable
6 days (approximately)
2.8 hours
635 g (22.4 oz)
200 x 108 x 44 mm (7.875 x 4.25 x 1.75 in)
Plastic, polycarbonate (Lexan 940
equivalent)
Factory Mutual (FM) approval and Canadian
Standards Association (CSA) certifications in the
following categories:
Nonincendive:
Class I; Division 2; Groups A, B, C, D
Intrinsically Safe:
Class I; Division 1; Groups A, B, C, D
in Section 6 for spare parts information.
®
or
REPAIR/REPLACE-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents