2 Installation and commissioning
2.3.2 Manually releasing the brakes
Continued
Supplying power to connector R1.MP
If the robot is not connected to the controller, power must be supplied to connector
R1.MP in the robot base in order to enable the brake release unit on the robot.
1
2
3
60
Action
CAUTION
Be careful not to interchange the 24 VDC and 0V
pins! If they are mixed up, damage can be caused
to a resistor diode and to the system board.
Connect an external power supply to connector
R1.MP, at the robot base.
Supply:
•
+24 V on pin B8
•
0 V on pin C10
Release the brakes with the brake release unit as
detailed in the previous procedure.