ABB IRB 2400/L Product Manual page 60

Hide thumbs Also See for IRB 2400/L:
Table of Contents

Advertisement

2 Installation and commissioning
2.3.2 Manually releasing the brakes
Continued
Supplying power to connector R1.MP
If the robot is not connected to the controller, power must be supplied to connector
R1.MP in the robot base in order to enable the brake release unit on the robot.
1
2
3
60
Action
CAUTION
Be careful not to interchange the 24 VDC and 0V
pins! If they are mixed up, damage can be caused
to a resistor diode and to the system board.
Connect an external power supply to connector
R1.MP, at the robot base.
Supply:
+24 V on pin B8
0 V on pin C10
Release the brakes with the brake release unit as
detailed in the previous procedure.
© Copyright 2004-2018 ABB. All rights reserved.
Note/Illustration
xx0200000167
Product manual - IRB 2400
3HAC022031-001 Revision: P

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 2400 seriesIrb 2400/10Irb 2400/16Irb 2400

Table of Contents