ABB IRB 2400/L Product Manual page 158

Hide thumbs Also See for IRB 2400/L:
Table of Contents

Advertisement

4 Repair
4.6.1 Replacement of SMB unit
Continued
8
9
10
11
12
13
14
158
Action
Gently disconnect the remaining connectors
from the SMB unit when pulling the board out.
Gently connect the connectors to the new
SMB unit and push the board in.
Make sure the lock on the battery cable con-
nector R2.G snaps into place during refitting.
Refit the SMB cover using the attachment lock
nuts.
Pull the battery cable through the hole in the
SMB cover.
Reassemble the two locknuts and washers to
the pins securing the board.
Refit the SMB battery.
Fit a new gasket to the cover and refit the
cover with the attachment screws.
Update the revolution counters!
© Copyright 2004-2018 ABB. All rights reserved.
Note
xx0600002645
A
B
C
xx1300000310
A Connector R2.SMB4-6
B Connector R2.SMB1-3S
C Connector R2.SMB1-2 (external
axis)
D Connector R2.SMB
E Connector R2.G (battery unit)
Always replace a removed gasket with
a new!
Art. no. is specified in
Required equip-
ment on page
154.
Detailed in the section
Updating revolu-
tion counters on page
210.
Product manual - IRB 2400