3 Maintenance
3.5.1 Cleaning the IRB 2400
Continued
Instructions for steam or high pressure water cleaning
ABB robots with protection types Foundry Plus, Wash, or Foundry Prime can be
cleaned using a steam cleaner or high pressure water cleaner.
The following list defines the prerequisites:
Cables
Movable cables need to be able to move freely:
2
See
Cleaning methods on page 101
102
•
Maximum water pressure at the nozzle: 2500 kN/m
•
Fan jet nozzle should be used, min. 45° spread
•
Minimum distance from nozzle to encapsulation: 0.4 meters
•
Maximum water temperature: 80° C
•
Remove waste material, such as sand, dust and chips, if it prevents cable
movement.
•
Clean the cables if they have a crusty surface, for example from dry release
agents.
for exceptions.
© Copyright 2004-2018 ABB. All rights reserved.
2
2
(25 bar)
Product manual - IRB 2400
3HAC022031-001 Revision: P