ABB IRB 2400/L Product Manual page 175

Hide thumbs Also See for IRB 2400/L:
Table of Contents

Advertisement

3
4
5
6
7
8
9
Product manual - IRB 2400
3HAC022031-001 Revision: P
Action
Disconnect the motor connectors R3.MP2 and
R3.FB2.
Remove the connection box by unscrewing its
three attachment screws and plain washers.
Use a marker pen to mark out the position of the
motor, if the same motor is to be refitted.
DANGER
Secure the weight of the lower arm properly before
releasing the brakes of motor, axis 2!
When releasing the holding brakes of the motor,
the lower arm will be movable and may fall down!
WARNING
Oil will be running out of the motor attachment
hole when removing the motor! It may also be hot!
Take any necessary measures to collect the oil.
Unscrew the four attachment screws and washers
of the motor.
Remove the motor by gently lifting it straight out.
© Copyright 2004-2018 ABB. All rights reserved.
4.7.2 Replacement of motor, axis 2
Note/Illustration
xx0200000401
A: R3.MP2
B: R3.FB2
C: Connection box
Secure the robot arms before un-
screwing any of the attachment
screws of the axis 2 motor.
xx0700000660
Shown in the figure
Location of mo-
tor, axis 2 on page
173.
Continues on next page
4 Repair
Continued
175

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 2400 seriesIrb 2400/10Irb 2400/16Irb 2400

Table of Contents