Applications That Require Auxiliary Power - Lucent Technologies DEFINITY Installation For Adjuncts And Peripherals

Enterprise communication server
Hide thumbs Also See for DEFINITY:
Table of Contents

Advertisement

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals 555-233-116
2
Auxiliary Power Supplies

Applications that require auxiliary power

Table 4. 302C1 Attendant Console Cabling Distances
With selector console:
Phantom-powered
Locally powered
Without selector console:
Phantom powered
Locally powered
Applications that require auxiliary
power
Auxiliary power (local or bulk) is always required for the following:
Any 8520 terminal
Attendant console 302C1
PassageWay adapter interface
Any 7500-series terminal whether in passive bus, or point to point (one per
BRI port)
Any 7500- or 8500-series terminal with an asynchronous data module
Any 8510 terminal in passive bus or with an asynchronous data module
(unless the 8510 will not be used to support data or video)
Any 7400-series terminal with XM24 expansion module
Any 7400-series terminal with adjuncts 7407, 7434 or 7444
Any 8400-series terminal with adjuncts 8411 or 8434
The 1145B power supply is required for all installations outside the United States.
24 AWG Wire
2
(0.27 mm
)
feet
meters
800
244
5000
1524
1400
427
5000
1524
Issue 1
April 2000
27 AWG Wire
2
(0.14 mm
)
feet
meters
500
152
3400
1037
900
274
3400
1037
6