DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals 555-233-116
14
DEFINITY INADS
Installation Test (All Installations)
These tests confirm that the hardware and administration are correct.
1. Place an outgoing call from the INADS port. Check for normal talk path.
2. Place an incoming call to the INADS port. Check for normal talk path.
3. Place an outgoing data from the INADS port to verify connection.
A failure in the link between the remote service center and the TN1648Bs INADS
port can be detected automatically.
1. Type change system-parameters maintenance and press
2. Set the Test Remote Access Port: field to y and press
Issue 1
April 2000
157
.
Enter
.
Enter