7. Enter 2 to set the station port to analog rotary. Enter 1 if an analog DTMF
telephone or PARTNER system telephone is connected.
8. Enter # to return to the start of the programming mode.
Set PARTNER CO Line Port (All Platforms)
1. Enter # 2 0 1.
2. Press 1 for tone or 2 for pulse mode.
3. Enter # to return to the start of the programming mode.
Set Automatic Line Selection — Outgoing Trunk
(All Platforms)
1. Press the right intercom (Central Tel Program) button.
2. Enter 1 5 (if INADS is connected to station 15) or enter the station number
connected to the INADS port.
3. Enter * *.
4. Press the line 1 button (above left intercom). If the 2 lines are connected to
the PARTNER for added reliability or security, press Next Procedure.
5. Enter * *.
6. Enter # to return to the start of the programming mode.
Set Incoming Line Ringing (All Platforms)
1. Press the right intercom (Central Tel Program) button.
2. Enter 1 5 (if INADS is connected to station 15) or enter the station number
connected to the INADS port.
3. Press the line 1 button (above left intercom) until the LED changes to a
steady green. This allows incoming calls to ring on line 1.
4. If AUDIX is installed, press the line 2 button until the LED changes to a
steady green. This allows incoming calls to ring on line 2.
5. Enter # to return to the start of the programming mode.
6. Press Feature, followed by 0 0 to exit the programming mode.
DEFINITY ECS Administration
By default, the INADS port automatically seizes an outgoing trunk on the
PARTNER system. Therefore, a "9" is not required in the switch dial string.