(3) Related Parameters
The following table lists parameters related to this function and their possibility of being changed while exe-
cuting this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes : Parameters can be changed using SigmaWin+ while this function is being executed.
No : Parameters cannot be changed using SigmaWin+ while this function is being executed.
• Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.
Parameter
Pn401
Torque Reference Filter Time Constant
Pn408
Torque Related Function Switch
Pn409
1st Notch Filter Frequency
Pn40A
1st Notch Filter Q Value
Pn40C
2nd Notch Filter Frequency
Pn40D
2nd Notch Filter Q Value
Name
7.22 Online Vibration Monitor (Fn207)
Mid-execution
Automatic
changes
changes
No
Yes
Yes
Yes
No
Yes
No
No
No
No
No
No
7