3 Wiring and Connection

3.1.5 Discharging Time of the Main Circuit's Capacitor

3.1.5

Discharging Time of the Main Circuit's Capacitor

The following table shows the discharging time of the main circuit's capacitor.
Input Voltage
Three-phase
200 VAC
Three-phase
400 VAC
3-20
Combinations
SERVOPACK Model:
Converter Model:
SGDV-
121H
161H
201H
750J
101J
131J
Discharging Time
[min.]
SGDV-COA
2BAA
20
3GAA
25
3GAA
30
3ZDA
5EDA
10
5EDA
10
5