YASKAWA Sigma-V Series User Manual page 409

Ac servo drives
Hide thumbs Also See for Sigma-V Series:
Table of Contents

Advertisement

Parameter
Size
No.
Position Control Reference Form
2
Selection Switch
4th 3rd 2nd 1st
digit digit digit digit
n.
Pn200
Pn205
2
Multiturn Limit Setting
Setting
Name
Range
0000 to 2236
Reference Pulse Form
0
Sign + Pulse train, positive logic
1
CW + CCW pulse train, positive logic
Two-phase pulse train with 90° phase differential (phase A + phase B) ×1, positive logic
2
Two-phase pulse train with 90° phase differential (phase A + phase B) ×2, positive logic
3
Two-phase pulse train with 90° phase differential (phase A + phase B) ×4, positive logic
4
5
Sign + Pulse train, negative logic
6
CW + CCW pulse train, negative logic
Clear Signal Form
0
Clears position error when the signal is at high level.
1
Clears position error at the rising edge of the signal.
2
Clears position error when the signal is at low level.
3
Clears position error at the falling edge of the signal.
Clear Operation
0
Clears position error at the baseblock (servomotor power OFF or alarm occurred).
1
Does not clear position error (possible to clear error counter only with CLR signal).
2
Clears position error when an alarm occurs.
Filter Selection
0
Uses reference input filter 1 for line driver signal (to 1 Mpps).
1
Uses reference input filter for open collector signal (to 200 kpps).
2
Uses reference input filter 2 for line driver signal (1 Mpps to 4 Mpps).
0 to 65535
Factory
Units
When Enabled
Setting
0000
After restart
1 rev
65535
After restart
11.2 List of Parameters
(cont'd)
Classifi-
Reference
cation
Section
Setup
Reference
Section
5.4.1
Reference
Section
5.4.2
Reference
Section
5.4.2
Reference
Section
5.4.1
Setup
5.9.6
11
11-21