YASKAWA Sigma-V Series User Manual page 140

Ac servo drives
Hide thumbs Also See for Sigma-V Series:
Table of Contents

Advertisement

(2) Related Parameters
Parameter
n.
0
[Factory setting]
n.
1
Pn008
n.
2
Torque Limit at Main Circuit Voltage Drop
Pn424
Setting Range
0 to 100
Release Time for Torque Limit at Main Circuit
Voltage Drop
Pn425
Setting Range
0 to 1000
The setting unit is a percentage of the rated torque.
Instantaneous Power Cut Hold Time
Pn509
Setting Range
20 to 50000
Note: When using SEMI F47 function, set 1000 ms.
Meaning
Does not detect undervoltage.
Detects warning and limits torque by host controller.
Detects warning and limits torque by Pn424 and Pn425.
(Only in the SERVOPACK)
Setting Unit
*
1%
Setting Unit
1 ms
Setting Unit
1 ms
When Enabled Classification
After restart
Speed
Position
Factory Setting
When Enabled
50
Immediately
Speed
Position
Factory Setting
When Enabled
100
Immediately
Position
Speed
Factory Setting
When Enabled
20
Immediately
5.2 Basic Functions Settings
Setup
Classification
Torque
Setup
Torque
Classification
Setup
Torque
Classification
Setup
5-19
5

Advertisement

Table of Contents
loading

Table of Contents