7 Utility Functions (Fn
(1) Preparation
There are no tasks that must be performed before the execution.
(2) Operating Procedure
Follow the steps to set enable or disable writing.
Setting values are as follows:
P.0000
"
P.0001
"
Step
1
2
3
4
5
6
7-22
)
: Write permitted (Releases write prohibited mode.) [Factory setting]
"
: Write prohibited (Parameters become write prohibited from the next power ON.)
"
Display after
Operation
MODE/SET
MODE/SET
MODE/SET
MODE/SET
MODE/SET
To enable the change in the setting, turn the power OFF and ON again.
Keys
Press the MODE/SET Key to select the utility function.
DATA/
Press the UP or DOWN Key to select Fn010.
DATA/
Press the DATA/SHIFT Key for approximately one second.
The display shown on the left appears.
DATA/
Press the UP or DOWN Key to set a value:
P.0000: Write permitted [Factory setting]
P.0001: Write prohibited
DATA/
Press the MODE/SET Key to register the value. When the
setting has been completed, "donE" flashes on the display
and the screen returns to the state shown on the left.
Note: If any value other than P.0000 or P.0001 is set,
DATA/
"Error" will be displayed on the screen.
Operation