YASKAWA Sigma-V Series User Manual page 80

Ac servo drives
Hide thumbs Also See for Sigma-V Series:
Table of Contents

Advertisement

3 Wiring and Connection
3.4.1 Input Signal Allocations
(3) Example of Input Signal Allocation
The procedure to replace Servo ON (/S-ON) signal allocated on CN1-40 and Forward External Torque Limit
(/P-CL) allocated on CN1-45 is shown below.
Step
1
2
3
4
5
6
7
8
9
10
11
12
3-32
Pn50A
Pn50B
Display after
Operation
MODE/SET
MODE/SET
MODE/SET
MODE/SET
MODE/SET
Display flashes.
MODE/SET
MODE/SET
MODE/SET
MODE/SET
MODE/SET
Display flashes.
MODE/SET
To enable the change in the setting, turn the power OFF and ON again.
Before
After
Keys
Press the MODE/SET Key to select the parameter setting. If a
parameter other than Pn50A is displayed, press the UP or
DOWN Key to set Pn50A.
DATA/
Press the DATA/SHIFT Key for approximately one second to
display the current data of Pn50A.
(/S-ON is allocated on CN1-40.)
DATA/
Press the UP key to set to the value on the far right "1"
(Pn50A.0 = 1).
(Sequence input signals can be freely set.)
DATA/
Press the DATA/SHIFT Key to select the second digit from
the right. Press the UP key to set to "5."
(Changes the allocation of /S-ON from CN1-40 to CN1-45.)
DATA/
Press the MODE/SET Key.
The data flashes and is saved.
DATA/
Press the DATA/SHIFT Key for approximately one second to
return to the display Pn50A.
DATA/
Press the UP key to display Pn50B.
DATA/
Press the DATA/SHIFT Key for approximately one second to
display the current data of Pn50B.
(/P-CL is allocated on CN1-45.)
DATA/
Press the DATA/SHIFT Key to select the third digit from the
right. Press the UP Key to set "0."
(Changes the allocation of /P-CL from CN1-45 to CN1-40.)
DATA/
Press the MODE/SET Key.
The value flashes and is saved.
DATA/
Press the DATA/SHIFT Key for approximately one second to
return to the display Pn50B. /S-ON is mapped on CN1-45,
and /P-CL is mapped on CN1-40.