3 Wiring and Connection
3.8.6 Connections
(2) Using a Dynamic Brake Resistor from Another Company
Using NO Contacts for the Dynamic Brake Contactor
The above figure is for using a dynamic brake contactor with NO contacts. The dynamic brake answer signal (a signal
from NO auxiliary contacts) is input to CN1-45. To indicate an error if the input signal to CN1-45 turns OFF (open)
while the dynamic brake is activated, the Pn515 parameter in the SERVOPACK must be set to n. E
dynamic brake answer signal is not used, Pn515 is set to n. 8
Note 1. If you assign more than one signal to the same input circuit, OR logic will be used and any of the input signals
2. The maximum current for DB24 and DBON is 300 mA.
3-52
SERVOPACK
CN1
47
Dynamic brake contactor
45*
DU
DV
DW
CN115
24 V
DB
DB24
DBON
0 V
DB
will cause the circuit to operate. This may result in unexpected operation.
For I/O
power supply
24 V
0 V
(Auxiliary contacts)
Dynamic brake resistor
Main circuit surge
absorption unit
Coil surge
absorption unit
(default setting).
. If the