YASKAWA Sigma-V Series User Manual page 87

Ac servo drives
Hide thumbs Also See for Sigma-V Series:
Table of Contents

Advertisement

24 V
+
Input Signal Polarities
Signal
Level
Low (L)
ON
level
High (H)
OFF
level
(2) Safety Input Circuit
As for wiring input signals for safety function, input signals make common 0 V. It is necessary to make an
input signal redundant.
Input Signal Connection Example
24-V power supply
Fuse
Sink Circuit
SERVOPACK input
Voltage
Contact
Level
0 V
Close
24 V
Open
SERVOPACK
CN8
Switch
/HWBB1+ 4
3.3 kΩ
3.3 kΩ
/HWBB1-
3
6
3.3 kΩ
/HWBB2+
3.3 kΩ
/HWBB2-
5
3.5 Examples of Connection to Host Controller
Source Circuit
24 V
SERVOPACK input
+
Input Signal Polarities
Voltage
Signal
Level
Level
High (H)
ON
level
Low (L)
OFF
level
Contact
24 V
Close
0 V
Open
3-39