9.1 System Configuration and Connection Example for SERVOPACK with Fully-closed Loop Control
When Using an External Encoder with Multiple Zero Points and Passing 1st Zero Point in
Forward Direction and Returning after Power ON
When using an external encoder with multiple zero points, the same logic as that explained earlier for an
encoder with only one zero point applies to each zero point.
See
When Passing 1st Zero Point in Forward Direction and Returning after Power ON.
Scale count-up
direction
Zero point 1 detection position
Zero point 2 detection position
Power ON
Phase-C pulse output
The phase-C pulse is also output when passing this point
in reverse, because the SERVOPACK has recorded
the position where the phase-C pulse was originally output
when first passing the position in the forward direction.
When Using an External Encoder with Multiple Zero Points and Passing 1st Zero Point in
Reverse Direction and Returning after Power ON
When using an external encoder with multiple zero points, the same logic as that explained earlier for an
encoder with only one zero point applies to each zero point.
See
When Passing 1st Zero Point in Reverse Direction and Returning after Power ON.
Scale count-up
direction
Zero point 1 detection position
Zero point 2 detection position
Zero point 3 detection position
Phase-C pulse output
To output the phase-C pulse when a detection point is passed in reverse, set the following parameter to 1.
Parameter
n.
0
[Factory Setting]
Pn081
n.
1
Zero point 1
Zero point 1
Power ON
Zero point 1
Zero point 2
Zero point 2
Zero point 2
Phase-C pulse is not output when passing
a zero point in reverse direction.
Meaning
Outputs phase-C pulse only in forward direction.
Outputs phase-C pulse in forward and reverse
direction.
Zero point 2
Zero point 2
Even after zero point 1 has first been passed
in the forward direction, the phase-C pulse is not
output here because zero point 2 is passed
in reverse direction.
Zero point 3
Zero point 3
When Enabled
After restart
Time
Time
9
Classification
Setup
9-9