YASKAWA Sigma-V Series User Manual page 57

Ac servo drives
Hide thumbs Also See for Sigma-V Series:
Table of Contents

Advertisement

(3) Wire Size (UL Standard)
To comply with the UL standard, use the recommended wires.
The following table shows the wire sizes (AWG) at a rating of 75 °C.
For Three-phase, 200V
Combination of SERVOPACK and
Converter
SERVOPACK
SGDV-121H
SGDV-
COA2BAA
SERVOPACK
SGDV-161H
SGDV-
COA3GAA
SERVOPACK
SGDV-201H
SGDV-
COA3GAA
Use SERVOPACKs and converters in the specified combinations.
Terminal Symbols
*
P, N
U, V, W
DU, DV, DW
P, N
L1, L2, L3
1,
Converter
CN101
(L1C, L2C)
B1, B2
P, N
U, V, W
DU, DV, DW
P, N
L1, L2, L3
1,
Converter
CN101
(L1C, L2C)
B1, B2
P, N
U, V, W
DU, DV, DW
P, N
L1, L2, L3
1,
Converter
CN101
(L1C, L2C)
B1, B2
Tightening
Screw Size for
Terminals
M8
M8
M6
M8
M8
M8
M8
2
(Connector)
M8
M8
M8
M8
M6
M8
M10
M10
M10
2
(Connector)
M10
M8
M10
M10
M6
M8
M10
M10
M10
2
(Connector)
M10
M8
3.1 Main Circuit Wiring
Torque
Wire Size AWG
(N m)
Bus bar attached
15.0
to the converter
3.0
1/0
3.0
10
9.0 to 11.0
1/0
Bus bar attached
3.0
to the converter
3.0
1/0
3.0
1/0
14
3.0
6
9.0 to 11.0
1/0
Bus bar attached
15.0
to the converter
3.0
3/0
3.0
10
9.0 to 11.0
3/0
Bus bar attached
12 to 20
to the converter
12 to 20
3/0
12 to 20
3/0
14
12 to 20
4
9.0 to 11.0
3/0
Bus bar attached
12 to 20
to the converter
30.0
250
3.0
10
9.0 to 11.0
250
Bus bar attached
12 to 20
to the converter
12 to 20
4/0
12 to 20
4/0
14
12 to 20
4
9.0 to 11.0
4/0
3
3-9